Integrator’s Reference Manual
6-28 80-99208-1 Rev. D
Power-On/Reset Default Value(s)
Results Returned
See Table 6-4 on page 6-24 for result code details.
Connection Completion Timeout (S7)
Syntax
S7{=<value>|?}
Description
Specifies the number of seconds to establish an end-to-end
data connection. The modem will disconnect the line if no
connection is established within this time. See Silent Retry
Timeout (S777) on page 6-31 for similar (Globalstar-specific)
control.
This parameter is valid only for asynchronous data services.
It is sent to the Gateway IWF modem if different from the
default value but is otherwise not used by the modem.
Valid Value(s)
Missing Parameter Default Value(s)
N/A
Power-On/Reset Default Value(s)
Results Returned
See Table 6-4 on page 6-24 for result code details.
2 seconds
1-255 Number of seconds to establish a connection or call
will be disconnected
50 seconds
Seitenansicht 132