IS-707 AT Commands (CDMA)
80-VG756-1 G 57 Qualcomm Confidential and Proprietary
MAY CONTAIN U.S. AND INTERNATIONAL EXPORT CONTROLLED INFORMATION
3.3 In-band control AT command 1
Table 3-15 In-band control AT command 2
AT command Command purpose
IS-707
requirement
Explanation
+IBC*
In-Band Control Compound
Parameter. The AT+IBC
compound parameter provides
for the enabling, disabling, and
configuration of in-band
control service. See Section 8
of ANSI/TIA/EIA-617 for a
complete description of this
command.
Async: N/A
Pkt: opt
Optional for packet service. Needed
for in-band control over R
m
interface.
This capability not implemented by
Qualcomm.
3
3.4 Cellular identification AT command 4
Table 3-16 Cellular identification AT command 5
AT command Command purpose
IS-707
requirement
Explanation
+CGCAP*
This extended-format
command causes the IWF to
transmit one or more lines of
information text in a specific
format. The content is a list of
additional capabilities
command +<name>s, which is
intended to permit the user of
the IWF to identify the
minimum capabilities of the
IWF.
IWFs conforming to this
standard shall include the
following items, as a minimum,
in the result code for the
+CGCAP command*:
+CIS707, +MS, +ES, +DS,
+FCLASS
Async: opt
Pkt: N/A
Remote Async/Fax command
Released - Internal Use Only
Released - Internal Use Only